Views: 0 Author: Site Editor Publish Time: 2026-10-28 Origin: Site
Cable tray must be given room to expand and contract whenever temperature changes are large enough, or the run is long enough, for the movement to matter. Metal gets longer as it warms and shorter as it cools, and a tray that is fixed rigidly along its whole length has nowhere to take that movement up. The result can be buckled sections, stressed supports, loosened joints, and damaged cables. Expansion joints solve this by letting the tray slide at planned points. This guide explains why movement happens, where expansion joints are needed, how they work, and what to check during installation.
Situation | Why movement matters | Expansion joint usually needed? |
|---|---|---|
Long straight run, indoors in a stable temperature | Small temperature change, so small movement | Often not, but follow the project specification |
Long straight run, outdoors or on a roof | Daily and seasonal temperature swings are large | Yes, at spacing set by the designer or manufacturer |
Tray crossing a building expansion or settlement joint | The building itself moves at that point | Yes, at the crossing |
Run between hot and cold areas | Large temperature difference along the run | Usually, at the transition |
Aluminum tray | Aluminum moves more than steel for the same temperature change | More often, at shorter spacing than steel |
Every metal grows slightly when its temperature rises and shrinks when it falls. On a short run the change is too small to notice. On a long run, or one that sees a wide temperature range, the total movement can add up to a significant amount. Different metals move by different amounts: aluminum expands more than steel for the same temperature change, so aluminum tray usually needs more allowance than steel tray. The exact movement depends on the material, the length, and the temperature range, and it is calculated by the designer from the project's conditions.
Tray sections can bow or buckle between fixed supports
Splice joints can loosen, crack, or pull apart
Supports and anchors can be overloaded and work loose
Cables can be pulled or crushed where the tray moves
On long straight runs, especially outdoors, expansion joints are placed at intervals so that no single section has to absorb the full movement. The spacing depends on the material, the temperature range, and the manufacturer's guidance, so take it from the design and the manufacturer's instructions.
Outdoors, the tray sees sun, night cooling, and seasonal change, so the temperature range is much wider than indoors. Rooftop and exposed routes are the most common places where expansion joints are specified.
Where a tray run crosses a building expansion joint or settlement joint, the two sides of the building can move relative to each other. The tray must be able to follow that movement without breaking, so an expansion joint is placed at the crossing and the tray on each side is supported independently.
Where a run passes from a heated area to an unheated or outdoor one, one end of the tray can be at a very different temperature from the other. A joint at the transition lets the two parts move without stressing each other.
A typical expansion joint uses a splice plate with slotted holes, instead of round holes, so the bolts can slide in the slots as the tray moves. The bolts are fitted so they clamp the plate without locking the tray, and a gap is left between the tray ends to allow for movement. The tray on both sides of the joint is supported so that it can slide along its length at that point, while other points along the run are fixed.
Fixed (anchor) supports hold the tray in position and give the movement a defined starting point
Guide or sliding supports hold the tray sideways but let it move along its length
Expansion joints sit between fixed points so the movement is shared and controlled
Follow the layout in the drawings. The designer sets the position of expansion joints and fixed points, so do not add or remove them on site without approval.
Do not over-tighten the slotted joint bolts. They must hold the plate but still let the tray slide, and the manufacturer's instructions give the right setting.
Set the gap for the temperature at installation. The gap between tray ends depends on the temperature when the tray is installed, so follow the manufacturer's guidance.
Keep supports aligned. A guide support that binds or is out of line can stop the tray from moving.
Install a bonding jumper across every expansion joint. The sliding joint may not keep reliable electrical contact on its own (see our Cable Tray Grounding and Bonding guide for how to maintain continuity).
Leave cable slack where needed. Cables crossing the joint should not be pulled tight, so they can move with the tray.
Fixing a long outdoor run rigidly with no expansion joints, so the tray has to absorb all the movement.
Tightening slotted bolts fully, which turns the expansion joint into a rigid joint.
Forgetting the bonding jumper at the expansion joint, so electrical continuity is lost.
Using steel tray spacing for aluminum tray, when aluminum moves more.
Placing a fixed support right next to an expansion joint, so the movement cannot take place.
Crossing a building joint with a continuous tray and no allowance for building movement.
Cable tray expands and contracts with temperature, and the longer the run and the wider the temperature range, the more it matters. Expansion joints, placed at the right points and set up correctly with slotted splices, fixed and sliding supports, and bonding jumpers, let the tray move without damage. Take spacing and positions from the project design and the manufacturer's installation manual rather than from a general rule, and check every joint after installation. Our How to Install Cable Tray guide covers supports and splicing more generally, and our Cable Tray Materials Explained guide explains how material choice affects movement.
There is no single spacing that fits every project. It depends on the tray material, the temperature range, and the run length, and it is set by the designer or the manufacturer's instructions. Outdoor and rooftop runs normally need joints at regular intervals, and indoor runs in stable temperatures often need fewer.
Often yes, because aluminum expands more than steel for the same temperature change. That usually means shorter spacing between expansion joints, but the actual figures come from the design and the manufacturer, not a general rule.
Yes. A sliding expansion joint may not keep a reliable electrical connection on its own, so a bonding jumper is normally installed across it, using hardware that suits the tray material. Check that the jumper is flexible enough to allow the tray to move.
Planning a long or outdoor cable tray run? Browse our cable tray systems, including hot-dip galvanized perforated tray, or contact our team with your route length, environment, and cable details.
Whatsapp: +86-18823394830